Technology Advantage Appliances The Science of Smell Clients Case Studies FAQ Press Contact Us

 

Technology Advantage

The Prolitec advantage: Effective air treatment at less than one part per million concentration.

To deal with odors and create a pleasing ambience, it is no longer necessary to saturate a space with heavy concentrations of scent and environmentally unfriendly VOCs (volatile organic compounds). Prolitec’s nano-droplet generation technology represents a genuine breakthrough in the use of liquids for air treatment applications including Odor Remediation, Ambient Scenting, Product Advertising, Restroom Hygiene, and Aromatherapy and Performance.

The essence of the Prolitec breakthrough is the use of tiny droplets and the ability to produce them with consistent sizes and controllable quantities from both aqueous and non-aqueous liquids. In air treatment applications, these droplets serve as transport vehicles for air treatment agents such as fragrances and odor neutralizers to blend with the ambient air in interior spaces.

Conventional aerosols produce droplets that vary in size between 30 and 100 microns in diameter. Prolitec droplets consistently measure less than 1 micron (1). Relative to a conventional aerosol droplet of, say, 50 microns in diameter, the Prolitec droplets is 1/50 th the size, 1/125,000 the weight (2), and presents to the air more than 50 times more exposed surface area per unit of volume (3). Thus, the Prolitec droplet is highly effective at ultra-low concentrations of less than one part per million.

Importantly, the Prolitec droplet is produced with very low pressure and no heat insuring that the original chemical compound is not altered in any way. The Prolitec droplet is delivered into the air without the use of potentially harmful VOCs as propellants.

Droplets size makes a significant difference in air treatment performance. Here’s why:

Unlike heavier aerosol droplets which fall to the floor or other surfaces within minutes, Prolitec’s much smaller and very much lighter droplets behave like a “dry” gas remaining airborne for many hours (4), blending uniformly throughout an interior space and without leaving surface deposits.

A 50 times more exposed surface area-to-volume ratio gives the smaller Prolitec droplet a huge performance advantage over the conventional aerosol. More surface area means more contact between the air treatment agent and the air being treated. It means that ultra-low concentrations of chemical compounds amounting to less than one part per million (ppm) – well below allergenic and toxicity thresholds – achieve excellent odor remediation and scenting results.

Control of droplet size and number is critical to maintaining the head-space concentration levels so important in air treatment applications. Prolitec’s nano-droplet generation technology can produce output from immeasurably low quantities to 10 liters per hour. This technology also controls droplet size, rejecting all that are too large. The onboard computer system is programmable to control flow rate and output.

  1. Actual diameters are between 800 and 1,200 nanometers.
  2. This can be calculated using the formula for the volume of a sphere - V=лr 3(4/3)
  3. The surface area of 1 50um particle is 7.85e-9 m^2 while the area of 125,000 1 um droplet (same volume) is 3.93e-7 m^2. The surface area is therefore 50 times greater for the 125,000 1 um droplets than for the single 50 um droplet.
  4. It is estimated that a 1 micron droplet requires 14 hours to fall 6 feet
    Top